Check of a condition and replacement of the breaker of indexes of turn/alarm system
|
All considered models are equipped by a safety pillow. The pillow constantly is in "the guarded" condition and can work to (be inflated) at any moment at the connected battery. In order to avoid casual operation of a pillow (and receptions as a result of a trauma) each time at carrying out of any works with components of system of safety disconnect a negative wire from the battery. After a detachment of a wire from the battery before starting to work wait still at least two minutes (the system is equipped by the condenser to which time for a discharge is required). More in detail about work of system of safety the Section a safety Pillow - the general information see. |
The breaker of indexes of turn/alarm system represents канистрообразной the relay forms, providing blinking of lamps of indexes of turn/alarm system at inclusion of the corresponding switch. On models 1993 вып. Two separate blocks are established on a back wall of the service centre under the panel of devices from its driver's party. Models 1994 вып. Are equipped by one combined breaker placed in a box of the relay in a ware box (Relay Section - the general information).
|
Breakers of indexes of turn and the alarm system.
|
Regularly functioning breaker publishes at work well distinguishable clicks on hearing. Refusal of functioning of one of turn indexes accompanied by increase of frequency of clicks of the breaker speaks about failure of a corresponding lamp.
Simultaneous refusal of both indexes of turn can be caused safety lock failure, defect of the breaker, malfunction of the switch or infringement of quality of contact or conducting breakage in a contour. If external survey has revealed combustion of a safety lock of a contour before making its replacement check up electroconducting on short circuit presence.
For breaker replacement simply take it from a socket and insert on its place the new.
Track that the new breaker was identical on type old.
|