Check of a condition and repair of a heater of glass of a door of a back
The heater of glass of a door of a back represents a series of the horizontal elements pasted on a surface has flown down from its inside.
Small ruptures of elements can be eliminated without glass removal.
Check
|
Include ignition and a heater of glass of a door of a back.
Earth a negative wire of the voltmeter on the plug And, positive connect to the plug of Century
|
Verifying points of a heater of glass of a door of a back.
|
Voltmeter indications should lie in limits between 10 and 15 V.Menshee value of pressure speaks about infringement of quality of grounding.
Connect a negative wire of the voltmeter to well earthed point - the indication should not change.
Connect a negative wire to the plug And, then serially touch probeом a positive wire an average point of each of lines of a lattice of a heater.
The instrument reading should make each time about 6 V.Nulevoe the voltmeter indication testifies to breakage presence between an average point With and the plug of Century
The indication in 10 - 14 In specifies in breakage presence between an average point With and A.Perevedite's plug probe towards breakage; after crossing of the last the indication will change.
|
|
Repair
|
For restoration of the torn off elements of a lattice it is recommended to use special repair sets of type MOPAR № 4267922 (or its equivalent). The set contains токопроводный plastic эпоксидный компаунд.
Before the beginning of restoration of an element switch off a heater allow to it to cool down within several minutes.
Slightly rub the damaged site with a thin rigid wool, then wipe its spirit.
Paste an insulating tape from both parties from the damaged site in parallel an element line.
|
For restoration of the damaged site of a horizontal element of a lattice of a heater paste from both parties on a strip изоляционной tapes.
|
Carefully get mixed up компаунд according to the instructions applied on a set.
Put компаунд in a gleam between insulating tape strips on the damaged site of an element, having blocked its healthy edges approximately on 20 mm.
Allow компаунду to rise within 24 hours, then it is possible to remove an insulating tape and to test a heater.
|
|
|